The LectroCount™ LCR 600, the latest edition of Liquid Controls’ popular LectroCount™ line of electronic registers, is loaded with advanced functionalities that can produce real savings for your bottom line. New features—such as the large 5.7" QVGA display and the alphanumeric keyboard—enable valuable new functionalities like the full-featured point-of-sale (or POS, an optional upgrade), instant diagnostic messaging, and customized delivery screens.  The LCR 600 is a standalone unit; no extraneous lap top or a lap pad is required. All configurations—including calibration, system setup, and point-of-sale (POS)—can be entered using the alphanumeric keypad.


Design Features

LectroCount LCR 600 Benefits

LectroCount LCR 600 with/ Point-of-Sale (POS) Benefits

LectroCount™ LCR-II
DMS i1000 Mobile Computing System


Specifications

REPEATABLILITY: Capable of .03% of reading over entire range.
LINEARITY: Capable of ±0.10% or better over a 5:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.10% or better over a 10:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.15% or better over a 40:1 range from maximum nominal meter capacity.

Due to the capabilities of multi-point calibration for meters equipped with LectroCount™Electronic Registration, superior accuracy (linearity) can be provided as indicated above.

NOTE: Accuracy obtainable when all variables remain constant. Reading/ measurements must be equal to a minimum of one minute of flow at selected rate(s). All accuracy statements based on metering Stoddard Solvent, approximate viscosity 1 CPS. On higher viscosity products, the average deviation in accuracy will be even less.

Power Requirements:
LectroCount® LCR-II: +9 - 28 VDC
LectroCount® LCR 600:  +9 - 28VDC

Environmental:
Enclosure:  Class 1, Division 2, Group C&D design, Nema 4X
Operating Temp Range:  -40° to 158°F (-40° to 70°C)

Approvals:
US Weights & Measures:  LCR-II and LCR 600
Measurement Canada:  LCR-II, LCR 600 pending

Communications:
RS232/485
Printer:  Epson, Okidata and Blaster Models

Electrical:
Power:  +9 to 28VDC, 3A maximum (including solenoid valves)

Inputs:
Temperature input: 4-Wire Platinum RTD
Pulse Inputs:  +5 to 28 volt peak to peak, open collector, single channel or quadrature

Outputs:
Control Valve (2):  Open drain transistor for 2 stage valve control, 1A Max. per channel
Auxiliary (2):  Open drain transistor for general purpose auxiliary control.  Aux(1) 1A Max, Aux(2) 150mA Max
Scaled Pulse Output:  Open drain output, 1 A Max.