Electronic Large Numeral Counter

Materials of Construction

The Liquid Controls LectroCount Remote display is perfect for aviation refuelers, load racks, and other applications in vast spaces where long-distance viewing is necessary, the 2¼" six-digit LectroCount Remote Display is viewable from 100 feet. It is also backlit for night viewing.

Design Features

Features include:


LectroCount® LCR-II
LectroCount® LCR 600
Electronic Registration


Specifications

Environmental
Design for: Class I, Div. 2, Group C & D NEMA 4X
Operating Temp. Range*: -22º to 158º F (-30º to 70º C)

Approvals

US Weights & Measures: NTEP COC 86-022
Canada Weights & Measures: AV-2342

Electrical
Power: +5 to 15 VDC, 500 mA, Maximum
*At lower temperatures, the liquid crystal display may have a delayed
response rate.

Signal Input
Input Signal Levels: Hi ≥2.50 VDC
Lo ≤2.0 VDC

Maximum Frequency Input:
Signal Source: Frequency
LectroCount LCR 5 kHz
LectroCount LCR-II N/A
LectroCount LCR 600 N/A
LectroCount LC3 5 kHz