Materials of Construction
LectroCount® is Liquid Controls’ series of electronic registers that replaces the mechanical register, calibration gears and/ or adjuster mechanism traditionally used on many flow meters. The LectroCount® series are Weights & Measures (custody transfer) approved advanced microprocessor based electronic register, presetting and printing control systems. LectroCount® is designed to meet - even adapt to - your flow meter and process control instrumentation requirements. Units are design to NEMA-4x non-incendive Class 1, Division 2, Group C & D. LectroCount® accepts pulse input from most flow meters and includes RS232/485 communications capability. The LCR-II is also available in a design for Class 1, Division 1 environments. |
Two models of LectroCount® registers are available, the LCR-II and LCR 600. The LCR-II has been a standard in electronic registrations since its first appearance as the LCR-I in 1997. The LCR 600 is the next generation of electronic registration, incorporating a large display for displaying more information during a delivery as well as incorporating a keypad to eliminate the need for external devices to configure the unit. The LCR 600 also has a Point-of-Sale option that provides the ability to flexibly set prices, discounts and taxes for 100 products.
LectroCount® LCR-II
LectroCount® LCR 600
DMS i1000 Mobile Computing System
REPEATABLILITY: Capable of .03% of reading over entire range.
LINEARITY: Capable of ±0.10% or better over a 5:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.10% or better over a 10:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.15% or better over a 40:1 range from maximum nominal meter capacity.
Due to the capabilities of multi-point calibration for meters equipped with LectroCount™Electronic Registration, superior accuracy (linearity) can be provided as indicated above.
NOTE: Accuracy obtainable when all variables remain constant. Reading/ measurements must be equal to a minimum of one minute of flow at selected rate(s). All accuracy statements based on metering Stoddard Solvent, approximate viscosity 1 CPS. On higher viscosity products, the average deviation in accuracy will be even less.
Power Requirements:
LectroCount® LCR-II: +9 - 28 VDC
LectroCount® LCR 600: +9 - 28VDC
Environmental:
Enclosure: Class 1, Division 2, Group C&D design, Nema 4X
Operating Temp Range: -40° to 158°F (-40° to 70°C)
Approvals:
US Weights & Measures: LCR-II and LCR 600
Measurement Canada: LCR-II, LCR 600 pending
Communications:
RS232/485
Printer: Epson, Okidata and Blaster Models
Electrical:
Power: +9 to 28VDC, 3A maximum (including solenoid valves)
Inputs:
Temperature input: 4-Wire Platinum RTD
Pulse Inputs: +5 to 28 volt peak to peak, open collector, single channel or quadrature
Outputs:
Control Valve (2): Open drain transistor for 2 stage valve control, 1A Max. per channel
Auxiliary (2): Open drain transistor for general purpose auxiliary control. Aux(1) 1A Max, Aux(2) 150mA Max
Scaled Pulse Output: Open drain output, 1 A Max.
LectroCount Brochure
LCR 600 Brochure
LectroCount for Load Rack Brochure
Installation and Operation Manuals
Contact us for more information.
Accessories: