Print Version
Pulse Output Device (POD)
|
Housing: Aluminum Wetted parts: 316 Stainless Steel Static seals: Buna or Viton
|
The LC Pulse Output Device (POD) converts the rotary motion created during the process of fluid measurement through an LC Meter into a high resolution, unscaled pulse stream. This pulse stream is provided by a magnetically coupled optical encoder that has a signal which is directly proportional to the liquid flow through the meter.
Glandless Drive...
No dynamic seals to fail and leak. All wetted parts are 316 Stainless Steel or equivalent. Meets Weights and Measures requirements. Weatherproof UL/CSA Type 4X and IP66 design. High Resolution, Square Wave, Single or Dual Channel Pulse Output.
- Voltage: (V+): +8 to +24 VDC (POD5 is +5 VDC) ±5%.
- Current supply: 26 mA typical.
- Output Signal Resolution: 100 pulses per encoder revolution, unscaled.
- Square Wave: Single or dual quadrature channel output.
- Pulse Timing: Nominal 50% on and 50% off.
- Rise/Fall Time of Pulse: <5 μs.
- Operating Temperature Range: -40ºF to +185ºF (-40ºC to +85ºC).
- Humidity Range: 0-100 %, noncondensing.
- Output: Current sinking 100 mA maximum in “ON” state; V+ supply @ 1.0 KW in “OFF” state. Optional Open Drain FET (Field Effect Transistor). FET rating (drain to source voltage) +30 VDC maximum.
- Shock: 50 G’s for 10 ms.
- Vibration: 1 G at 10-150 Hz.
- Electromagnetic Compatibility (EMI, RFI, etc.): to IEC 801 Standard.
- Pulse Transmission Distance: Up to 5,000 feet (1,524 meters).
- Operates in bidirectional flow applications.
Product Overview
Contact us for more information.
Print Version