Print Version

LectroCount® family of Electronic Registers


Electronic Registration:

LectroCount® is Liquid Controls’ series of electronic registers that replaces the mechanical register, calibration gears and/ or adjuster mechanism traditionally used on many flow meters.  The LectroCount® series are Weights & Measures (custody transfer) approved advanced microprocessor based electronic register, presetting and printing control systems. LectroCount® is designed to meet - even adapt to - your flow meter and process control instrumentation requirements. Units are design to NEMA-4x non-incendive Class 1, Division 2, Group C & D. LectroCount® accepts pulse input from most flow meters and includes RS232/485 communications capability.  The LCR-II is also available in a design for Class 1, Division 1 environments.


Two models of LectroCount® registers are available, the LCR-II and LCR 600.  The LCR-II has been a standard in electronic registrations since its first appearance as the LCR-I in 1997.  The LCR 600 is the next generation of electronic registration, incorporating a large display for displaying more information during a delivery as well as incorporating a keypad to eliminate the need for external devices to configure the unit.  The LCR 600 also has a Point-of-Sale option that provides the ability to flexibly set prices, discounts and taxes for 100 products.

LectroCount® LCR-II
LectroCount® LCR 600
DMS i1000 Mobile Computing System
i-Meter


Specifications

REPEATABLILITY: Capable of .03% of reading over entire range.
LINEARITY: Capable of ±0.10% or better over a 5:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.10% or better over a 10:1 range from maximum nominal meter capacity.
LINEARITY: Capable of ±0.15% or better over a 40:1 range from maximum nominal meter capacity.

Due to the capabilities of multi-point calibration for meters equipped with LectroCount™Electronic Registration, superior accuracy (linearity) can be provided as indicated above.

NOTE: Accuracy obtainable when all variables remain constant. Reading/ measurements must be equal to a minimum of one minute of flow at selected rate(s). All accuracy statements based on metering Stoddard Solvent, approximate viscosity 1 CPS. On higher viscosity products, the average deviation in accuracy will be even less.

Power Requirements:
LectroCount® LCR-II: +9 - 28 VDC
LectroCount® LCR 600:  +9 - 28VDC

Environmental:
Enclosure:  Class 1, Division 2, Group C&D design, Nema 4X
Operating Temp Range:  -40° to 158°F (-40° to 70°C)

Approvals:
US Weights & Measures:  LCR-II and LCR 600
Measurement Canada:  LCR-II, LCR 600

Communications:
RS232/485
Printer:  Epson, Okidata and Blaster Models

Electrical:
Power:  +9 to 28VDC, 3A maximum (including solenoid valves)

Inputs:
Temperature input: 4-Wire Platinum RTD
Pulse Inputs:  +5 to 28 volt peak to peak, open collector, single channel or quadrature

Outputs:
Control Valve (2):  Open drain transistor for 2 stage valve control, 1A Max. per channel
Auxiliary (2):  Open drain transistor for general purpose auxiliary control.  Aux(1) 1A Max, Aux(2) 150mA Max
Scaled Pulse Output:  Open drain output, 1 A Max.


Literature

LectroCount Brochure
LCR 600 Brochure
LectroCount for Load Rack Brochure
Installation and Operation Manuals
LectroCount Delivery Tickets

Contact us for more information.


Accessories:
LectroCount™ electronic registers are available with a selection of accessories including optical air eliminators, two stage valves, printers, remote displays and that integrate with electronic registers to provide more control and accuracy during deliveries.